What is New with CEREC SW 5.2.4?

 

Changes and Updates in CEREC SW 5.2.4

CEREC Primemill Changes

New Firmware version: 2.6.8-V122021

  • Reduces boot-up errors where the device remains on DS logo screen. (Note: A manual restart may be needed after firmware installation)
  • Optimized computation of device axes in calibration routine for improved restoration surfaces. (Note: Calibrate the device post firmware installation for effectiveness)
  • Fixed touch issues including “Error: spindle speed not reached” during touch process or calibration.
  • Optimized touch process routines for errors like “wrong block” or “wrong tools” even if setup is correct.
  • Fixed device freezing if the door is opened during a process.
  • Error messages now displayed for internal communication errors due to electronic issues.

Software (SW) Changes

  • Optimized pin strategy for MCXL-family and CEREC Primemill milling units. This increases usable block material allowing for longer restorations, mainly zirconia bridges in medi blocks.
  • Demos on Dry sintering and Glazing of CEREC MTL Zirconia and CEREC Tessera.

Demos Included

  1. Dry sintering of CEREC MTL Zirconia (shade A1, A3.5)
  2. Dry sintering of CEREC MTL Zirconia (shade A2, C2)
  3. Glazing of CEREC MTL Zirconia (all shades)
  4. Glazing of CEREC Tessera
  5. Dry sintering of CEREC Zirconia+ (wall thickness between 3.0 – 3.5 mm)

Further Changes

  • Bug fixes for increased software stability.
  • Indications introduced with Primeprint are visible post CEREC SW 5.2.4 installation. Note: Primeprint area in configuration and selection in manufacturing phase have been omitted.
  • Updated quality agreement during the installation process.

New Materials

Manufacturer Material Customization

Manufacturer Material Customization
Dentsply Sirona CEREC Tessera Abutment Activation of MIS Ti bases in CE Abutment. Design parameter adjustment from 1.0 mm to 0.0 mm
Dentsply Sirona CEREC MTL Zirconia Multijob option for SpeedFire: Up to 3 restorations of the same color can be sintered in SpeedFire
3M Chairside Zirconia Multijob option for SpeedFire: Up to 3 restorations can be sintered in SpeedFire

DS System Monitor v.1.1

  • New function for deleting .ent files (raw scan data before model calculation) to free up hard disk space. Caution: Editing a patient case post-deletion is not possible.